E164 Associations ( N to N DN )

Overview

This topic describes managing a range of internal numbers (Directory Numbers, or DNs) associated with a range of E164 numbers.

View Ranges of E164 Numbers Associated with a Range of Internal Numbers

To view the ranges of E164 numbers that are associated with a range of internal numbers (Directory Numbers, or DNs), go to (default menus) Number Management > E164 Associations (N to N DN) to open the E164 Associations ( N to N DN ) list view.

You can filter the list and change the hierarchy by selecting a link in the Located At column.

The table describes the information available on the E164 Associations ( N to N DN ) list view:

Column

Description

E164 Number

The starting E164 number in the range.

DN Number

The starting internal number in the range.

Range

One of the following:

  • 1 - To indicate that one E164 number and internal number are associated.

  • 10 - To indicate that a range of ten numbers including the starting E164 and starting internal number are associated.

  • 100 - To indicate that a range of 100 numbers including the starting E164 and starting internal number are associated.

  • 1000 - To indicate that a range of 1000 numbers including the starting E164 and starting internal number are associated.

Located At

Indicates the hierarchy of the site where the E164 number range and internal number range association was created.

Associate a Range of E164 Numbers to a Range of Internal Numbers

THis procedure associates one E164 number to one internal number, at a site.

Note

  • You can also perform the association in ranges of 10, 100, and 1000, on a one-to-one basis. These associations create Direct Dial Inward (DDI) associations so that incoming PSTN numbers are routed to internal numbers.

  • Only internal numbers or E164 numbers that are not currently associated, are available for association.

  • In VOSS Automate, the HcsSipLocalGwAddE164AssociationEVT event related to SIP Local Gateway is generated

  1. Go to (default menus) Number Management > E164 Associations (N to N DN).

  2. Choose the site (if required).

  3. In the E164 Associations ( N to N DN ) list view, click Add to open a new record.

  4. On the New Record page, choose values for the following options:

Field

Description

Range

Select one of these ranges:

Notes:

The range values you select map to the mask value when the association translation pattern is created. For example, when 10 is selected, all E164 numbers and directory numbers that end in 0 are listed. The mask affects all digits 0 to 9, so you can’t start the mask on a non zero number. Likewise, when 100 is selected, the E.164 number and DN end in two zeros. This pattern results in a mask of XX.

  • 1 - To list all E164 numbers and internal numbers

  • 10 - To list all E164 numbers and internal numbers that end in one zero (0)

  • 100 - To list all E164 numbers and internal numbers that end in two zeros (00)

  • 1000 - To list all E164 numbers and internal numbers that end in three zeros (000)

This field is mandatory and affects what appears in the fields that follow.

E164 Number*

Choose the starting number of the range of E164 numbers from the drop-down. This field is mandatory.

Notes:

  • If the association is performed at customer level, the drop-down only shows E164 numbers that were added at customer level.

  • If the association is performed at site level, the drop-down contains E164 numbers that were added at either customer or site level provided the country matches the site’s country.

DN Number*

Choose the starting internal number from the drop-down menu. This field is mandatory.

Notes:

  • If the association is performed at customer level, the drop-down only shows internal numbers that were added at customer level.

  • If the association is performed at site level, the drop-down shows internal numbers that were added at either customer or site level.

  • You cannot associate internal numbers that begin with the prefix ‘*’ (asterisk) or ‘#” (hash).

  1. Click Save.

    Note

    • When listing the Number Inventory and displaying an internal number, the E164 Number format is as listed in E164 Numbers in the Number Inventory.

    • A translation pattern (which is the mapping between the E164 range and internal number range) is created on the CUCM. This translation pattern is used to route inbound PSTN calls to their associated internal numbers.

    • If the association is performed at a Site, the translation pattern is only added to the CUCM referenced by the site’s network device list (NDL).

    • If the association is performed at Customer level, the translation pattern is added to all the customer’s CUCMs.

    • If the Site has one or more SIP Local Gateways associated with it, the HcsSipLocalGwAddE164AssociationEVT event is generated. If enabled, the IOS Command Builder generates the default IOS commands associated with the event for each SIP Local Gateway.

Disassociate a Range of E164 Numbers from a Range of Internal Numbers

This procedure disassociates a range of E164 numbers from a range of internal numbers.

Note

In VOSS Automate, the HcsSipLocalGwDelE164AssociationEVT event related to SIP Local Gateway is generated as a result.

  1. Go to (default menu) Number Management > E164 Associations (N to N DN) to open the E164 Associations ( N to N DN ) list.

  2. Change your hierarchy, if required.

  3. View E164 Associations (N to N DN) in the list, which displays the following information:

Column

Description

E164 Number

The starting E164 number in the range.

DN Number

The starting DN number in the range.

Range

  • 1 - Indicates that one E164 number and internal number are associated

  • 10 - Indicates that a range of ten numbers including the starting E164 and starting internal number are associated

  • 100 - Indicates that a range of 100 numbers including the starting E164 and starting internal number are associated

  • 1000 - Indicates that a range of 1000 numbers including the starting E164 and starting internal numbers are associated

Located At

Indicates the hierarchy of the site where the E164 number range and internal number range association was created.

  1. Choose an option:

    • To disassociate multiple ranges, select the check boxes in the far left column of the table for the ranges you want to disassociate.

    • To disassociate one range, click its row in the table. The details about the association appear.

  2. Click Delete.

  3. Click Yes to confirm the disassociation.

    Note

    • The translation pattern mapping between the E164 range and internal number range is deleted from CUCM.

      The E164 number association with the internal number is removed on the Number Inventory list view display and in any Lines drop-down list and Lines displays.

    • If the site has one or more SIP Local Gateways associated with it, the HcsSipLocalGwDelE164AssociationEVT event is generated. If enabled, the IOS Command Builder generates the default IOS commands associated with the event for each SIP Local Gateway.