Manage Range of Internal Numbers Associated with a Range of E164 Numbers¶
View the Ranges of E164 Numbers Associated with a Range of Internal Numbers¶
Use this procedure to view the ranges of E164 numbers that are associated with a range of Internal Numbers (Directory Numbers - DNs).
On the E164 Associations ( N to N DN ) list (default menu Number Management > E164 Associations (N to N DN).
You can filter the list and change the hierarchy by selecting a link in the Located At column. A table containing this information is displayed:
Column |
Description |
---|---|
E164 Number |
The starting E164 number in the range. |
DN Number |
The starting internal number in the range. |
Range |
One of the following:
|
Located At |
Indicates the hierarchy of the site where the E164 number range and internal number range association was created. |
Associate a Range of E164 Numbers to a Range of Internal Numbers¶
Use this procedure to associate a single E164 number to a single internal number at a site. The association can also be done in ranges of 10, 100 and 1000 on a one-to-one basis. These associations create Direct Dial Inward (DDI) associations so that incoming PSTN numbers are routed to internal numbers.
Note
In VOSS Automate, the
HcsSipLocalGwAddE164AssociationEVT
event related to SIP Local Gateway is generated (see Considerations below).Only internal numbers or E164 numbers that are not currently associated are available for association.
Procedure:
From the E164 Associations ( N to N DN ) list (default menu Number Management > E164 Associations (N to N DN).
Click Add and select the site (if required).
Provide the following information:
Field |
Description |
---|---|
Range |
Select one of these ranges: Notes: The range values you select map to the mask value when the association translation pattern is created. For example, when 10 is selected, all E164 numbers and directory numbers that end in 0 are listed. The mask affects all digits 0 to 9, so you can’t start the mask on a non zero number. Likewise, when 100 is selected, the E.164 number and DN end in two zeros. This pattern results in a mask of XX.
This field is mandatory and affects what appears in the fields that follow. |
E164 Number* |
Choose the starting number of the range of E164 numbers from the drop-down. This field is mandatory. Notes:
|
DN Number* |
Choose the starting internal number from the drop-down menu. This field is mandatory. Notes:
|
Click Save.
Considerations:
When listing the Number Inventory and displaying an internal number, the E164 Number format is as listed in E164 Column - Number Inventory List.
A translation pattern that is used to route inbound PSTN calls to their associated internal numbers is created on the Unified CM. This pattern is the mapping between the E164 range and internal number range.
If the association is performed at site level the translation pattern will only be added to the Unified CM referenced by the site’s network device list (NDL).
If the association is performed at customer level then the translation pattern will be added to all of the Unified CMs that exist for the customer.
If the site has one or more SIP Local Gateways associated with it, the
HcsSipLocalGwAddE164AssociationEVT
event is generated. If enabled, the IOS Command Builder generates the default IOS commands associated with the event for each SIP Local Gateway.
Disassociate a Range of E164 Numbers from a Range of Internal Numbers¶
Use this procedure to disassociate a range of E164 numbers from a range of internal numbers.
Note
In VOSS Automate, the HcsSipLocalGwDelE164AssociationEVT
event related to SIP
Local Gateway is generated as a result.
Procedure:
From the E164 Associations ( N to N DN ) list (default menu Number Management > E164 Associations (N to N DN).
You can change your hierarchy if needed.
An E164 Associations (N to N DN) table containing this information is displayed:
Column |
Description |
---|---|
E164 Number |
The starting E164 number in the range. |
DN Number |
The starting DN number in the range. |
Range |
|
Located At |
Indicates the hierarchy of the site where the E164 number range and internal number range association was created. |
Perform one of these options:
To disassociate multiple ranges, select the check boxes in the far left column of the table for the ranges you want to disassociate.
To disassociate one range, click its row in the table. The details about the association appear.
Click Delete.
Click Yes to confirm the disassociation.
Considerations:
The translation pattern mapping between the E.164 range and internal number range is deleted from Unified CM.
The E164 number association with the internal number will be removed on the Number Inventory list view display and in any Lines drop-down list and Lines displays.
If the site has one or more SIP Local Gateways associated with it, the
HcsSipLocalGwDelE164AssociationEVT
event is generated. If enabled, the IOS Command Builder generates the default IOS commands associated with the event for each SIP Local Gateway.