E164 Associations ( N to 1 DN )#
Overview#
This topic describes managing single internal numbers associated with a range of E164 numbers.
View E164 Associations (N to 1 DN)#
This procedure displays sets of E164 numbers associated with a single internal number (directory number, or DN).
Go to (default menus) Number Management > E164 Associations (N to 1 DN).
On the E164 Associations ( N to 1 DN ) list, view E164 Associations (N to 1 DN).
Note
You can filter the list and change the hierarchy by selecting a link in the Located At column.
The table describes column data in the E164 Associations (N to 1 DN) list view:
Column
Description
DN Number
The associated internal number (directory number).
Located At
The hierarchy of the site where the E164 number range and internal number association was created.
Click on a directory number in the list to view its details.
The page displays read-only details about the E164 Association (N to 1 DN) configuration (the sets of E164 numbers that are associated with the internal number):
DN Number
The number you’re viewing.
Primary E164
Displays the E164 number associated to the internal number in the Number Inventory.
Other E164s are indicated as [x] showing that there are more associated E164s to this internal number but their details are only available when opening the relevant Number Inventory.
.
Add E164 Association (N to 1 DN)#
This procedure associates multiple E164 numbers (a set of E164 number) to a single internal number, at a site. For example, you could associate a set of E164 numbers for the sales department with an attendant’s internal number.
Note
You can also perform association in ranges of 10, 100, and 1000, on a one-to-one basis. These associations create Direct Dial Inward (DDI) associations so that incoming PSTN numbers are routed to internal numbers.
You can optionally specify a primary E164 number to associate with the internal number. This is useful when performing an internal number to E164 translation (for example, when provisioning translation rules for LBO gateways) and the internal number is associated to more than one E164 presentation.
You can only associate internal numbers or E164 numbers that are not currently associated.
Prerequisites:
Enable number management for the customer.
Perform these steps:
Go to (default menu) Number Management > E164 Associations (N to 1 DN) to open the list view.
Choose the site (if required).
In the E164 Associations ( N to 1 DN ) list view, click the Plus icon (+) to add a new record.
Configure E164 Association ( N to 1 DN ). The table describes configuration options:
Field |
Description |
---|---|
DN Number |
Choose an internal number.
|
E164 Ranges |
Click the Plus icon (+) to add one or more sets of E164 numbers. These E164 numbers do not need to be contiguous. For each E164 number you add, choose an E164 range and the E164 number, as follows:
This field is mandatory and affects what appears in the E164 Number field. |
E164 Number |
Mandatory. Choose the starting number of E164 numbers.
|
Primary E164 |
Optional. Fill out the primary E164 number to
associate with the internal number. Ensure the
E164 number you enter starts with |
Dial Plan Model Selection |
This field displays only when the Enforce HCS Dialplan Rules setting in the Global Settings is set to False Defines the translation pattern template configured in the dial plan modeling tool. The values for the pattern, transform mask, and associated range masking are hard coded in the workflow. +1555 111 5555 (Range 10) = +1555 111 555X Other values, such as partition and CSS) come from this template. The translation pattern must have its description set to display in this drop-down. |
Save your changes.
View transaction progress and details in the Transaction Logs.
Note
When listing the number inventory and displaying an internal number, the E164 number format is as listed in E164 Numbers in the Number Inventory.
One or more translation patterns are created on the CUCM. The translation patterns are the mappings between the set of E164 numbers and the single internal number, and are used to route inbound PSTN calls to their proper internal numbers.
When you associate a set of E164 numbers to a single internal number, multiple translation patterns are created (each DN-to-E164 range association results in a translation pattern being created on the CUCM).
If the association is performed at Site level, the translation pattern is only added to the CUCM referenced by the site’s network device list (NDL).
If the association is performed at Customer level, the translation pattern is added to all of the CUCMs that exist for the customer.
If the site is associated with one or more SIP Local Gateways, the
HcsSipLocalGwAddMultiE164AssociationEVT
event is generated. If enabled, the IOS Command Builder generates the default IOS commands associated with the event for each SIP Local Gateway.
Related Topics
Delete an E164 Associations (N to 1 DN) Association#
This procedure disassociates a set of E164 numbers from an internal number.
Note
When disassociating a set of E164 numbers from an internal number, multiple translation patterns are deleted. For each association you delete, a translation pattern is deleted from the CUCM.
In VOSS Automate, the
HcsSipLocalGwDelMultiE164AssociationEVT
event related to SIP Local Gateway is generated as a result.If the Local Gateway is set up to override the Voice Translation limit and the Enable Command Builder setting is enabled, disassociation will fail if it exceeds the default Voice Translation limit. In this case, first disable the Enable Command Builder setting.
Go to (default menu) Number Management > E164 Associations (N to 1 DN).
Change the hierarchy, if required.
In the E164 Associations ( N to 1 DN ) list, view the following details:
Column |
Description |
---|---|
DN Number |
The internal number. |
Located At |
The hierarchy of the site where the E164 number range and internal number range association was created. |
Choose an option:
To disassociate multiple associations, click the check box in the far left column of the table, next to the numbers you want to disassociate.
To disassociate one association, click its row in the table. The details about the association appear.
Click Delete, then click Yes to confirm the disassociation.
Note
The translation pattern mapping between the E164 set and the internal number is deleted from the CUCM.
The E164 number association with the internal number is removed from the Number Inventory list view, and from any Lines drop-downs and Lines displays.
If the site is associated with one or more SIP Local Gateways, the
HcsSipLocalGwDelMultiE164AssociationEVT
event is generated. If enabled, the IOS Command Builder generates the default IOS commands associated with the event for each SIP Local Gateway.
Related Topics