VOSS Automate supports the integration of numbers used by AudioCodes devices into the Number Inventory. Once such devices are configured in VOSS Automate and data is synced, the Number Inventory displays these numbers as Status is Used, with the Vendor field set as AudioCodes. These numbers are therefore then not available to assign to subscribers during number management.
Workflows and data syncs are in place to ensure these numbers in the Number Inventory remain aligned with any changes in these devices.
see: AudioCodes Devices
AudioCodes and Number Cooling
In the case of the removal (or delete) of a AudioCodes RegisteredUsers instance, the internal number is placed into a configurable cooling period, with Status as Cooling.
Important
For AudioCodes internal numbers, the cooling period (days) is configured by means of a named macro called: audiocodes_cooling_duration (default setting is 2 days) and not by the Number Inventory Cooling Duration (Days) value in Global Settings (Global Settings).
A high level administrator with access to the named macro instances can carry out this configuration if needed.
The reason for the alternative cooling setting is that AudioCodes devices can become offline but are not deleted. The default maximum offline duration is here set to 2 days.
In addition, if the device does then come back online within the days set in the macro, the internal number will be set back to:
When the line is in Cooling, the following internal number inventory fields are set:
See: Number Inventory List View.
When the Release Date has been reached, the INI is put back into the Available pool of INI's, as with standard cooling - see: Number Cooling.
AudioCodes and Audit Number Inventory
When the Audit Number Inventory is run, the Status and Usage of internal number inventory items that have the Vendor field set as AudioCodes are checked and verified to be:
See:
This relation implements the workflows to manage Microsoft Operator Connect connection parameters and enabled services.
Title | Description | Details | |||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Name * | AudioCodes Connection defined name, can be an IP address or a host name and can have a max length of 255 charactors |
|
|||||||||||||||||||||||||||||||||||||||||||||||
Description | AudioCodes Connection defined description. |
|
|||||||||||||||||||||||||||||||||||||||||||||||
Audio Codes Routing Manager * | AudioCodes Connection host, can be an IP address or a host name. |
|
|||||||||||||||||||||||||||||||||||||||||||||||
Username * | AudioCodes Connection service account. |
|
|||||||||||||||||||||||||||||||||||||||||||||||
Password * | AudioCodes Connection password of the above service account. |
|
|||||||||||||||||||||||||||||||||||||||||||||||
Authentication Method | Type of authentication to use when interfacing to the external service. |
|
|||||||||||||||||||||||||||||||||||||||||||||||
AudioCodes Connection sync on Create/Update | Sync AudioCodes Connection on Create and Update. When this checkbox is checked it will execute a full Pull Sync from the AudioCodes Connection. |
|
|||||||||||||||||||||||||||||||||||||||||||||||
Version * | Version Default: v1.0 |
|
|||||||||||||||||||||||||||||||||||||||||||||||
Shadow |
|
||||||||||||||||||||||||||||||||||||||||||||||||
Name * |
|