[Index]
Overview
The Number Range management feature allows you to create a range of internal numbers at a customer, site or intermediate node in the hierarchy. The latter option allows for number ranges to be available for all sites below the intermediate nodes.
When adding a range that includes existing numbers, these cannot be modified. New unused numbers will be added only to complete the range. In other words, the range will show up as complete, with unused numbers in between numbers imported from Unified CM.
Number ranges can also be deleted. Numbers in the range that have a status of Used, Used-Utility, Reserved or Cooling will be ignored and can not be deleted. If these numbers are modified to the Available status, and not in use, they can then be deleted. The Available and Reserved status of numbers can also be modified manually once they are added.
Note
Add, Modify, or Delete a Number or Number Range
Numbers can be added or deleted. When modifying a number, you can only edit the free text fields. The usage and availability property for each number is associated with a line or taken into use by a service.
Since the number inventory is not partition aware, if the same directory number is used on a cluster but in different partitions, then VOSS Automate workflows will update the inventory when any of those instances are changed. For instance, if there is a number 1111 in the Cluster X partition and a number 1111 in the Cluster Y partition, then the number is marked as Used.
If one of those instances are deleted, we check to see if there are other instances of that line based on the number only (not partition), before clearing the Used flag. In this case, the other instance will be found and the inventory will stay marked as Used.
Browse to the hierarchy at which you want manage the number range.
Open the Number Range Management form (default menu Number Management > Number Range Management) and choose the target site from the Target Site drop-down (only applicable to Customers using an SLC-based dial plan).
From the Operation drop-down, choose Add, Modify or Delete.
Note
Enter the Starting Extension and Ending Extension. The maximum allowed range is 1000 for a single action. The starting extension should always be smaller than the ending extension.
If you are adding or deleting a single number, the starting and ending extension number will be the same. If numbers in the range already exist, they will not be affected - only non-existing numbers will be added.
If Vendor is "Microsoft", then Internal Number Type should be set.
Internal Number Type: If Vendor is "Microsoft", then for connectivity options with MS Teams and Phone System, the drop down value can be any of: "Direct Routing", "Calling Plan", "Operator Connect". The value can be managed and is used to determine user configuration when the number is assigned. [1] If Vendor = "Cisco", then blank.
Edit free text fields, for example Tag, Description, Reservation notes E164Number (if applicable), and Extra1 to Extra9.
Click Save to save the single or range of numbers that you added, modified or deleted. If a number in a deleted range was set as Used, it will not be deleted.
The numbers at a specific hierarchy can be viewed on the Number Inventory list view (default menu Number Management > Number Inventory). See Number Inventory List View.
When a line is added and selected from the drop-down list of available numbers, it has a status of Used. If the line is used by a device or service that does not allow a shared line (for example, a Hunt Pilot), it has a status of Used-Utility. See Number Status and Usage.
If number cooling is enabled, deleted numbers are automatically placed into a cooling period as specified in Global Settings. During this period the number cannot be used.
Internal numbers are available when adding subscribers.
Modify an individual number
You can also modify an individual number from the list view (Number Inventory List View) by selecting it.
Persisting and Modifying Values in Extra Fields
Note the following properties of the extra fields Extra1 to Extra9:
When managing the Number Inventory, users can modify the fields Extra1 to Extra9.
When the status of a number changes from for example Used to Available (for example, when an associated device is unassociated with the line), then any values originally of the fields Extra1 to Extra9 remain unchanged by default.
A default custom Configuration Template (CFT) called IniUpdateCustomCFT that applies to data/InternalNumberInventory is available to clone to the user hierarchy and then to modify the custom persistence of extra field values. For details on CFT cloning and custom configuration, refer to the Advanced Configuration Guide.
Important
Any changes to this custom CFT only apply to updates in workflows resulting in number status changes - manual updates are not affected.
The following default values in this CFT can be modified according to your needs:
"description": "{{ pwf.ini_dat_before.description }}", "extra1": "{{ pwf.ini_dat_before.extra1 }}", "extra2": "{{ pwf.ini_dat_before.extra2 }}", "extra3": "{{ pwf.ini_dat_before.extra3 }}", "extra4": "{{ pwf.ini_dat_before.extra4 }}", "extra5": "{{ pwf.ini_dat_before.extra5 }}", "extra6": "{{ pwf.ini_dat_before.extra6 }}", "extra7": "{{ pwf.ini_dat_before.extra7 }}", "extra8": "{{ pwf.ini_dat_before.extra8 }}", "extra9": "{{ pwf.ini_dat_before.extra9 }}", "tag": "{{ pwf.ini_dat_before.tag }}"
The default macros for each extra field can thus be replaced inside the cloned CFT with custom text and macros as needed. Use the macro {{ macro.CLEAR }} if it is necessary to clear a field.
The Description field is always cleared when the status of the number changes to Available, regardless of CFT value. For other number status changes, the CFT value will apply.
There is full customization functionality of the Description field available to allow values in accordance with VOSS Automate feature usage.
For details, see the Number Inventory Flexibility and Description Customization topic in the Advanced Configuration Guide.
[1] | "Direct Routing", "Calling Plan", "Operator Connect" are Microsoft PSTN connectivity options.
For details, refer to Microsoft documentation on PSTN connectivity options. |
Title | Description | Details | |||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Current Hierarchy Node Type (Informational) |
|
||||||||||||||||||||||||||||||||||||||||||||||||
Operation | Select operation Add, Modify or Delete. Default: Add |
|
|||||||||||||||||||||||||||||||||||||||||||||||
HCS Rules Enforced | Default: false |
|
|||||||||||||||||||||||||||||||||||||||||||||||
Target Site | Please choose Site to Provision DNs. If site not specified, inventory will be added to the current hierarchy node if allowed. |
|
|||||||||||||||||||||||||||||||||||||||||||||||
Starting Extension * | Starting Number for th DN Mgmt Range |
|
|||||||||||||||||||||||||||||||||||||||||||||||
Ending Extension | Ending Number for th DN Mgmt Range |
|
|||||||||||||||||||||||||||||||||||||||||||||||
Status | Initial status to apply to each Number Default: Available |
|
|||||||||||||||||||||||||||||||||||||||||||||||
Vendor |
|
||||||||||||||||||||||||||||||||||||||||||||||||
Internal Number Type |
|
||||||||||||||||||||||||||||||||||||||||||||||||
Reservation duration (days) |
|
||||||||||||||||||||||||||||||||||||||||||||||||
Reservation Notes |
|
||||||||||||||||||||||||||||||||||||||||||||||||
Extension Length | Extension Length for the current Site |
|
|||||||||||||||||||||||||||||||||||||||||||||||
Site Location Code | Site Location Code for the current Site |
|
|||||||||||||||||||||||||||||||||||||||||||||||
ISP | Inter-Site-Prefix (ISP) for the Customer |
|
|||||||||||||||||||||||||||||||||||||||||||||||
Customer-Dialplan is SLC-based | Site Location Code Based true or false |
|
|||||||||||||||||||||||||||||||||||||||||||||||
Tag | Tag used for filtering INI numbers. This can be any free text to identify or comment a range of internal numbers. |
|
|||||||||||||||||||||||||||||||||||||||||||||||
Description | Description field |
|
|||||||||||||||||||||||||||||||||||||||||||||||
E164Number | Number in E164 format |
|
|||||||||||||||||||||||||||||||||||||||||||||||
Extra1 | Extra field 1 |
|
|||||||||||||||||||||||||||||||||||||||||||||||
Extra2 | Extra field 2 |
|
|||||||||||||||||||||||||||||||||||||||||||||||
Extra3 | Extra field 3 |
|
|||||||||||||||||||||||||||||||||||||||||||||||
Extra4 | Extra field 4 |
|
|||||||||||||||||||||||||||||||||||||||||||||||
Extra5 | Extra field 5 |
|
|||||||||||||||||||||||||||||||||||||||||||||||
Extra6 | Extra field 6 |
|
|||||||||||||||||||||||||||||||||||||||||||||||
Extra7 | Extra field 7 |
|
|||||||||||||||||||||||||||||||||||||||||||||||
Extra8 | Extra field 8 |
|
|||||||||||||||||||||||||||||||||||||||||||||||
Extra9 | Extra field 9 |
|
|||||||||||||||||||||||||||||||||||||||||||||||
Webex Control Hub |
|
||||||||||||||||||||||||||||||||||||||||||||||||
Webex Configured | Does the site meet the requirements for webex |
|
|||||||||||||||||||||||||||||||||||||||||||||||
Push Numbers to Webex | Provision Numbers in the Webex Control Hub |
|
|||||||||||||||||||||||||||||||||||||||||||||||
Push as Active | Provision Numbers in the Webex Control Hub in ACTIVE state |
|
|||||||||||||||||||||||||||||||||||||||||||||||
Site Hierarchy PKID | PKID of site hierarchy |
|