Use this procedure to associate a set of E.164 numbers with one Directory Number (DN) at a customer or site. For example, you could associate a set of E.164 numbers for the sales department with an attendant's DN.
If you create the association at a site, you can mix customer-level DNs and E.164 numbers with site-level DNs and E.164 numbers.
You can optionally specify a primary E.164 number to associate with the DN. This step can be useful when you perform a DN-to-E.164 translation (for example, when provisioning translation rules for LBO gateways) and the DN is associated to more than one E.164 presentation.
Note
To access the flowcharts, view the topic via Documentation and Resources at: https://voss.portalshape.com
Procedure
Choose Dial Plan Management > Number Management > E164 Associations (N to 1 DN).
You can change the hierarchy if needed.
Click Add.
From the DN Number drop-down, choose an extension number. This field is mandatory.
In the E164 Ranges group, click + as required, to add multiple sets of E.164 numbers. The E.164 numbers do not need to be contiguous. Provide the following information:
Field | Description |
---|---|
E164 Range | Choose one of these ranges: Note: The range values you choose map to the mask value when the association translation pattern is created. For example, when 10 is chosen, all E.164 numbers and directory numbers that end in 0 are listed. The mask affects all digits 0 to 9, so you can't start the mask on a nonzero number. Likewise, when 100 is chosen, the E.164 number and DN end in two zeros. This pattern results in a mask of XX.
This field is mandatory and affects what appears in the E.164 Number field. |
E164 Number | Choose the starting number of E.164 numbers. For a customer-level association, customer-level E.164 numbers are available. For a site-level configuration, both customer-level and site-level E.164 numbers are available. This field is mandatory. |
In the optional Primary E164 field, enter the primary E.164 number to associate with the DN. Make sure the E.164 number you enter starts with \+ and falls within the range you specified in the E164 Range drop-down.
Click Save.
Notes
Overview
This topic describes managing single internal numbers associated with a range of E164 numbers.
View E164 Associations (N to 1 DN)
This procedure displays sets of E164 numbers associated with a single internal number (directory number, or DN).
Go to (default menus) Number Management > E164 Associations (N to 1 DN).
On the E164 Associations ( N to 1 DN ) list, view E164 Associations (N to 1 DN).
Note
You can filter the list and change the hierarchy by selecting a link in the Located At column.
The table describes column data in the E164 Associations (N to 1 DN) list view:
Column | Description |
---|---|
DN Number | The associated internal number (directory number). |
Located At | The hierarchy of the site where the E164 number range and internal number association was created. |
Click on a directory number in the list to view its details.
The page displays read-only details about the E164 Association (N to 1 DN) configuration (the sets of E164 numbers that are associated with the internal number):
DN Number | The number you're viewing. |
Primary E164 | Displays the E164 number associated to the internal number in the Number Inventory. Other E164s are indicated as [x] showing that there are more associated E164s to this internal number but their details are only available when opening the relevant Number Inventory. |
.
Add E164 Association (N to 1 DN)
This procedure associates multiple E164 numbers (a set of E164 number) to a single internal number, at a site. For example, you could associate a set of E164 numbers for the sales department with an attendant's internal number.
Note
You can also perform association in ranges of 10, 100, and 1000, on a one-to-one basis. These associations create Direct Dial Inward (DDI) associations so that incoming PSTN numbers are routed to internal numbers.
You can optionally specify a primary E164 number to associate with the internal number. This is useful when performing an internal number to E164 translation (for example, when provisioning translation rules for LBO gateways) and the internal number is associated to more than one E164 presentation.
You can only associate internal numbers or E164 numbers that are not currently associated.
Prerequisites:
Perform these steps:
Field | Description |
---|---|
DN Number | Choose an internal number.
|
E164 Ranges | Click the Plus icon (+) to add one or more sets of E164 numbers. These E164 numbers do not need to be contiguous. For each E164 number you add, choose an E164 range and the E164 number, as follows:
This field is mandatory and affects what appears in the E164 Number field. |
E164 Number | Mandatory. Choose the starting number of E164 numbers.
|
Primary E164 | Optional. Fill out the primary E164 number to associate with the internal number. Ensure the E164 number you enter starts with \+ and falls within the range you specified in in E164 Range |
Dial Plan Model Selection | This field displays only when the Enforce HCS Dialplan Rules setting in the Global Settings is set to False Defines the translation pattern template configured in the dial plan modeling tool. The values for the pattern, transform mask, and associated range masking are hard coded in the workflow. +1555 111 5555 (Range 10) = +1555 111 555X Other values, such as partition and CSS) come from this template. The translation pattern must have its description set to display in this drop-down. |
Save your changes.
Note
When listing the Number Inventory and displaying an internal number, the E164 number format is as listed in E164 Column Description.
One or more translation patterns are created on the CUCM. The translation patterns are the mappings between the set of E164 numbers and the single internal number, and are used to route inbound PSTN calls to their proper internal numbers.
When you associate a set of E164 numbers to a single internal number, multiple translation patterns are created (each DN-to-E164 range association results in a translation pattern being created on the CUCM).
If the association is performed at Site level, the translation pattern is only added to the CUCM referenced by the site's network device list (NDL).
If the association is performed at Customer level, the translation pattern is added to all of the CUCMs that exist for the customer.
If the site is associated with one or more SIP Local Gateways, the HcsSipLocalGwAddMultiE164AssociationEVT event is generated. If enabled, the IOS Command Builder generates the default IOS commands associated with the event for each SIP Local Gateway.
Delete an E164 Associations (N to 1 DN) Association
This procedure disassociates a set of E164 numbers from an internal number.
Note
When disassociating a set of E164 numbers from an internal number, multiple translation patterns are deleted. For each association you delete, a translation pattern is deleted from the CUCM.
In VOSS Automate, the HcsSipLocalGwDelMultiE164AssociationEVT event related to SIP Local Gateway is generated as a result.
If the Local Gateway is set up to override the Voice Translation limit and the Enable Command Builder setting is enabled, disassociation will fail if it exceeds the default Voice Translation limit. In this case, first disable the Enable Command Builder setting.
Column | Description |
---|---|
DN Number | The internal number. |
Located At | The hierarchy of the site where the E164 number range and internal number range association was created. |
Choose an option:
Click Delete, then click Yes to confirm the disassociation.
Note
The translation pattern mapping between the E164 set and the internal number is deleted from the CUCM.
The E164 number association with the internal number is removed from the Number Inventory list view, and from any Lines drop-downs and Lines displays.
If the site is associated with one or more SIP Local Gateways, the HcsSipLocalGwDelMultiE164AssociationEVT event is generated. If enabled, the IOS Command Builder generates the default IOS commands associated with the event for each SIP Local Gateway.
Title | Description | Details | |||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
DN Number * | The Directory Number. |
|
|||||||||||||||||||||||||||||||||||||||||||||||
E164 Ranges | The E164 ranges the DN is associated with. |
|
|||||||||||||||||||||||||||||||||||||||||||||||
E164 Range * | The E164 Range |
|
|||||||||||||||||||||||||||||||||||||||||||||||
E164 Number * | The starting E614 Number for the range. |
|
|||||||||||||||||||||||||||||||||||||||||||||||
Primary E164 | The Primary E164 for the ranges. |
|
|||||||||||||||||||||||||||||||||||||||||||||||
Evaluate HCS DP Enforcement | Default: false |
|
|||||||||||||||||||||||||||||||||||||||||||||||
Dial Plan Model Selection | Select the required Translation Pattern Dial Plan Model. Translation Pattern must have the Description field set to be displayed in this dropdown. |
|
|||||||||||||||||||||||||||||||||||||||||||||||
Shadow |
|
||||||||||||||||||||||||||||||||||||||||||||||||