[Index]

Model: device/cucm/MohServer

Model Details: device/cucm/MohServer

Title Description Details
Is Multi Cast Enabled If isMultiCastEnabled is false then these elements are not necessary. MOHServer will be added to the database without the values of these tags. ie. The table MOHServerMulticastInfo table will be empty. Multicast Base Port number must be an even number in the range 16384 to 32766.
  • Field Name: isMultiCastEnabled
  • Type: Boolean
  • Cardinality: [0..1]
Max Multicast Connections Maximum Multicast Connections must be a number in the range 0 to 999999. Default: 250000
  • Field Name: maxMulticastConnections
  • Type: Integer
  • Cardinality: [0..1]
  • Default: 250000
Name *
  • Field Name: name
  • Type: String
  • Cardinality: [1..1]
Use Trusted Relay Point Default: Default
  • Field Name: useTrustedRelayPoint
  • Type: String
  • Cardinality: [0..1]
  • Default: Default
  • Choices: ["Off", "On", "Default"]
Device Pool Name *
  • Field Name: devicePoolName
  • Type: ["String", "Null"]
  • Cardinality: [1..1]
Multicast Increment On Ip If isMultiCastEnabled is false then these elements are not necessary. MOHServer will be added to the database without the values of these tags. ie. The table MOHServerMulticastInfo table will be empty.
  • Field Name: multicastIncrementOnIp
  • Type: Boolean
  • Cardinality: [0..1]
Location Name *
  • Field Name: locationName
  • Type: String
  • Cardinality: [1..1]
Fixed Audio Source Device
  • Field Name: fixedAudioSourceDevice
  • Type: ["String", "Null"]
  • Cardinality: [0..1]
Max Unicast Connections Maximum Half Duplex Streams must be a number in the range 0 to 500. Default: 250
  • Field Name: maxUnicastConnections
  • Type: Integer
  • Cardinality: [0..1]
  • Default: 250
Base Multicast Port If isMultiCastEnabled is false then these elements are not necessary. MOHServer will be added to the database without the values of these tags. ie. The table MOHServerMulticastInfo table will be empty. Multicast Base Port number must be an even number in the range 16384 to 32766
  • Field Name: baseMulticastPort
  • Type: Integer
  • Cardinality: [0..1]
Audio Sources If isMultiCastEnabled is false then these elements are not necessary. MOHServer will be added to the database without the values of these tags. ie. The table MOHServerMulticastInfo table will be empty.
  • Field Name: audioSources
  • Type: ["Object", "Null"]
  • Cardinality: [0..1]
Audio Source
  • Field Name: audioSource.[n]
  • Type: Array
Source Id *
  • Field Name: audioSources.audioSource.[n].sourceId
  • Type: Integer
  • Cardinality: [1..1]
Max Hops Default: 2
  • Field Name: audioSources.audioSource.[n].maxHops
  • Type: Integer
  • Cardinality: [0..1]
  • Default: 2
Run Flag Default: True
  • Field Name: runFlag
  • Type: Boolean
  • Cardinality: [0..1]
  • Default: True
Process Node Name *
  • Field Name: processNodeName
  • Type: ["String", "Null"]
  • Cardinality: [1..1]
Base Multicast Ipaddress If isMultiCastEnabled is false then these elements are not necessary. MOHServer will be added to the database without the values of these tags. ie. The table MOHServerMulticastInfo table will be empty. Multicast Base Port number must be an even number in the range 16384 to 32766. baseMulticastIPAddress and baseMulticastPort must be a unique pair. All Multicast IP Addresses must be in the range 239.1.1.1 to 239.255.255.255 Default: 239.1.1.1
  • Field Name: baseMulticastIpaddress
  • Type: String
  • Cardinality: [0..1]
  • Default: 239.1.1.1
Description
  • Field Name: description
  • Type: String
  • Cardinality: [0..1]