[Index]

Model: data/RS_PBR_Config

Configure the Phone Based Registration Add-On

To access the latest documentation, go to Documentation and Resources at: https://voss.portalshape.com

Phone Based Registration Feature Reference

The Phone Based Registration Add-On supports a number of configuration parameters that manage how the service operates in a specific provider or customer environment. This configuration is implemented using the Services > Phone Based Registration > PBR Config menu item.

Configuration is on VOSS Automate user interface:

Figure 5: Sample PBR Config record

When configuring the PBR service for a specific hierarchy the following considerations are important:

  1. VOSS recommends that PBR configuration should only allow the replacement of phones with fake MACs with device name prefix starting with BAT.

    This ensures that it is never possible for a user to replace a phone that is in active use.

    Select the BAT Prefix Required check box.

  2. Is the use of PBR Device records required in this environment?

    1. The PBR device record provides a mechanism for administrators to explicitly specify that a device is eligible for phone based registration.

      Select the PBR Device Record Required check box if this is desired.

    2. The PBR device record allows the administrator to specify a PIN that should be used when performing phone based registration for a specific phone or for all phones at a site.

      Select the Pin Required check box.

    3. The PBR device record can be used to guarantee that the correct device is replaced in environments where Directory numbers are not unique within a Unified CM cluster, e.g. multiple Directory numbers are configured with same DN but located in different partitions.

      In this case, clear the UseSiteWidePIN check box.

Phone Registration Portal Port:

Phone Registration Portal Address:

Phone Registration Portal API User Credentials:

Phone Registration Service Hierarchy:

CUCM IP:

By default, VOSS Automate requires a PBR device record per device, but in some cases, it could be sufficient to use a single pin per site:

  1. In this case, select the UseSiteWidePIN check box.
  2. This provides limited security to ensure that a PIN is still required to register a phone, but reduces the operational burden by eliminating the need to provision a PBR device record for each phone.

Additional options:

Important

After saving the above configuration in VOSS Automate, you must restart the services by running the following CLI command on the primary node:

cluster run all app start phone-based-registration

Phone Based Registration Configuration

Model Details: data/RS_PBR_Config

Title Description Details
Name * Name of the configuration. This MUST always be Default Default: Default
  • Field Name: Name
  • Type: String
  • Default: Default
  • MaxLength: 128
BAT Prefix Required * Only allow registration of phones with device name starting with BAT Default: True
  • Field Name: BATPrefixRequired
  • Type: Boolean
  • Default: True
BAT DeviceName Format Macro that describes how BAT device names are to be generated. This should be BAT Default: {{ fn.zeropad pwf.extension, 12 }}
  • Field Name: BATDeviceNameFormat
  • Type: String
  • Default: {{ fn.zeropad pwf.extension, 12 }}
Auto Provision PBR * Auto Provision PBR Device record for Subscriber BAT phones
  • Field Name: AutoProvisionPBR
  • Type: Boolean
Pin Required * Is the use of a pin required Default: True
  • Field Name: PINRequired
  • Type: Boolean
  • Default: True
UseSiteWidePin * Allow the use of a single PIN per site. When this is set then the device name and extension should be set to SITE in a single PBR device record at the site level and a Partition should be specified.
  • Field Name: UseSiteWidePin
  • Type: Boolean
PBR Device Record Required * Is the use of a PBR Device Record Required When this is set to false, then it is possible to replace any BAT phone with Phone based registration Default: True
  • Field Name: PBRDeviceRecordRequired
  • Type: Boolean
  • Default: True
Phone Registration Portal Address Phone Registration Portal Address. In environments that make use of NAT the address for VOSS-4-UC can be unique for each customer - if this is the case then configuring per-customer PBR config becomes mandatory. If HTTP access is desired then this should be map to the IP address of primary VOSS-4-UC Unified Node, for HTTPS this should map to a Web proxy. Redundancy across web proxies can be achieved using external load balancer or DNS.
  • Field Name: portal_address
  • Type: String
Phone Registration Portal Port Phone Registration Portal Port. This should be either port 8412 for HTTP or 443 for HTTPS.
  • Field Name: portal_port
  • Type: String
Phone Registration Portal API User * Phone Registration API User. This should be username dedicated to providing access to PBR web service with a Restricted API access role
  • Field Name: portal_user
  • Type: String
Phone Registration Portal API Password * Phone Registration API Password. This should be password of API user. This information is encrypted in VOSS-4-UC database
  • Field Name: portal_password
  • Type: String
  • Is Password: True
  • Store Encrypted: True
Phone Registration service Hierarchy Phone Registration Service Hierarchy. This should be the hierarchy of the VOSS-4-UC Provider
  • Field Name: portal_hierarchy
  • Type: String
CUCM IP IP of CUCM that this config applies to. The IP must be accessible to VOSS-4-UC
  • Field Name: cucm
  • Type: String