.. _best_prac_RIS_API_Data_Collector_Interval: Recommended RIS API Data Collector Interval ------------------------------------------- .. _19.1.1|VOSS-489: .. _19.1.1|VOSS-349: As a guideline to determine the interval that the (RIS) data collector service should poll the Unified CM, consider that: * it takes about 14 minutes to collect information for around 200K phones on a cluster The default value of the **RIS API data collector interval**: ``43200`` seconds (12 hours) can be adjusted accordingly. .. note:: Collection processes run in parallel for each Unified CM on VOSS Automate. To adjust the value, refer to the System Monitoring Configuration section in the Advanced Configuration Guide.