Reporter Commands

The VOSS-4-UC Analytics CLI has a number of reporter commands

$ reporter
USAGE:
------
reporter connect                   - Connect to remote VOSS system
reporter http_connection           - Print http_connection for VOSS system
reporter http_connection <IP>|None - Set or remove manual http_connection for
                                       VOSS system
reporter test_connection           - Test remote mongo and VOSS system
                                       connection

The reporter connect and reporter test_connection commands are used during the install process, or during system management.

For installation details, refer to the Set Up Analytics topic in the VOSS-4-UC Analytics Install Guide.

  • reporter connect

    The command takes an IP address parameter, which is the target system primary database server address. To determine the VOSS-4-UC system primary database server IP address, log in the the VOSS-4-UC system and run the command database primary.

    Use this IP address as a host parameter and enter the password, for example:

    $ reporter connect
    host: 192.77.248.122
    pass:
    
  • reporter http_connection

    The VOSS-4-UC Analytics system web interface connects to a VOSS-4-UC node that runs its web server. The web proxy nodes on a target VOSS-4-UC system can be shown with the cluster status command.

    For example, for a standalone system, the command output of this command is None, since the web proxy nodes has the same address as the application and database. The example output of the command below is on a standalone VOSS-4-UC system:

    $ cluster status
    
    Data Centre: atlantic
       application : voss2-08[192.77.248.122]
    
          webproxy : voss2-08[192.77.248.122]
    
          database : voss2-08[192.77.248.122]
    
  • reporter http_connection <IP>|None

    The web interface of VOSS-4-UC Analytics can be set to a specified web proxy IP address, fully qualified domain name, or it can be reset to None.

  • reporter test_connection

    This test command is also used during the installation process. The example below shows command output when connected to a standalone VOSS-4-UC system.

    $ reporter test_connection
    MongoDB Connection established to 192.77.248.122
    Primary Connection is 192.77.248.122:27020